Summer comfort is now one of the criteria explicitly assessed in the EPC. This change reshapes the way renovation projects are planned: solar shading, ventilation and insulation need to be designed together, not treated as separate items. Creating a sustainable, comfortable interior means thinking in terms of a system, not a catalogue of finishes.
Summer comfort and thermal renovation: technical interfaces you can’t afford to overlook
Insulating the attic or adding internal wall insulation without reviewing the ventilation creates an imbalance. The building envelope becomes more airtight, summer heat gets trapped, and indoor air quality deteriorates. The decree of 27 March 2025 amending the requirements for energy audits emphasises this point: heat loss and the interfaces between renovation works must be addressed together.
In practice, a renovation project designed to improve summer comfort brings together three measures: external solar shading (brise-soleil, projecting shutters, façade overhangs), external roof insulation to limit downward heat transfer, and ventilation sized to remove residual heat overnight. Leaving out any one of these measures undermines the other two.
A common pitfall is to install high-performance insulation for winter, then add air conditioning to compensate for summer overheating. The EPC penalises this approach, as it now assesses cooling needs. Several resources explore these technical trade-offs, including Yvazur Construction’s home section, which covers the overall design of residential projects.

Insulation and ventilation in renovation: sequencing mistakes to avoid
The order in which work is carried out determines how effective it will be. Insulating before sizing the ventilation is like sealing a box without providing any airflow. Connections between insulated walls and windows, and between the ground floor and external walls, can create residual thermal bridges if these interfaces are not addressed at the right time.
The right technical sequence starts with an assessment of airflow before choosing the insulation material. A thorough audit first identifies heat-loss points, then sizes the mechanical ventilation system according to the habitable volume and the required air-change rate. Insulation comes next, with careful detailing at wall-to-roof and wall-to-floor junctions.
The decree of 16 June 2025 amending the decree on the EPC makes heat losses easier to identify and helps prioritise renovation work. This means homeowners can now see in their assessment which parts of the building are least efficient and start there, rather than focusing on an isolated cosmetic upgrade such as replacing the flooring.
Sustainable materials for a comfortable interior: wood, raw earth and bio-based materials
The choice of materials directly affects a room’s hygrothermal comfort. Solid wood, used for structural elements or finishes, naturally regulates ambient humidity and stores heat, with a useful thermal lag in summer. Raw earth (plasters and compressed earth blocks) provides thermal mass that standard plasterboard cannot.
Bio-based insulation materials (wood fibre, cellulose, hemp) offer a greater thermal lag than mineral wool, delaying the penetration of summer heat into living spaces. This factor is rarely highlighted in interior design articles, even though it determines how comfortable an attic room will actually be in July.
- Wood fibre used in a sarking system (external roof insulation): combines protection against overheating with the elimination of thermal bridges at the rafters
- Raw earth plaster on interior walls: adds thermal mass without excessive thickness and works with both contemporary and rustic styles
- Blown cellulose in an unconverted attic: offers good value for money, with a significantly longer thermal lag than glass wool
- Hollow clay blocks for heavy partitions: store coolness overnight and release it during the day

Renovation grants and project design: check eligibility before signing
Technical grant criteria directly influence how a project is designed, not just its budget. For a major renovation of a detached house, the choice of heating system can determine eligibility for MaPrimeRénov’. A package of works combining insulation, windows and ventilation but retaining a boiler that does not meet the scheme’s requirements could jeopardise funding.
Many homeowners request quotes before checking whether their technical choices meet the eligibility conditions. A project based on outdated criteria may become ineligible if the thresholds change between the design stage and the application submission.
- Check the home’s current EPC rating and the identified sources of heat loss before defining the scope of work
- Confirm that the proposed heating system meets the criteria in force on the date the application is submitted
- Cross-check ventilation requirements against the planned insulation level to avoid failing the audit
Interior layout and natural light: plan around orientation
Arranging living spaces according to solar orientation remains an underused renovation strategy. Moving the kitchen to the north side frees up the south-facing façade for the living room, which can then benefit from free solar gains in winter while being protected by brise-soleil in summer.
A layout with bedrooms facing east and living spaces facing south-west reduces heating and cooling needs. In a renovation, this reconfiguration may involve moving partitions or creating new openings, but the gains in comfort and energy consumption justify the investment.
Windows play a key role in maintaining this balance. Solar-control glazing on south-facing windows limits overheating without reducing daylight as much as external blinds. The balance between natural light and thermal protection depends on each case, taking into account the room’s depth and the height of the lintels.
Renovating a home so it stays comfortable all year round means recognising that interior design and thermal performance are not separate concerns. The choice of plaster, the position of a partition, the type of glazing: every aesthetic decision has a thermal impact. The current version of the EPC makes this reality measurable.